Brand Name: Techco
Model Number: 2HP TO 200HP
Place of Origin: CHINA
Air-cooled Condensing Unit For Freezer (-18C )and Blast Freezer(-35C)
Air-cooled Condensing Unit for Freezer with -18C from 3HP to 15HP.
Compressor is Bitzer or Copeland or Frascold or Maneurop Piston Compressor Middle and Low temperature.
Unit include: Liquid Receiver and dry filter,Oil separator,gas-liquid separator,liquid sight glass,solenoid valve,H/L pressure gauge and H/L pressure control and external rotor low noisy fan.
Temperature range: 0C to -18C/-18C to -25C/ -25C to -35C for frozen meat and fish.
Blast freezer is also avaliable for -35C/Meat center temperature is -15C.
Refrigerant: R404A
Voltage:380V/3/50HZ
220V/1/50HZ
220V/3/60HZ
460V/3/60HZ
Condensing Unit For Cold Room Freezer 3HP To 15HP.
Bitzer Compressor Semi Hermetic Compressor High Temperature Air-cool Condersing Unit:+5C to -35C
Model of units |
GXW3CQFZD |
GXW5CQFZD |
GXW10CQFD |
GXW7CQFZD |
||
Power |
3HP |
5HP |
10HP |
15HP |
||
Applicable Temperature(℃) |
-5℃ To -35℃ |
|||||
Refirgerant |
R404A |
|||||
Power Supply |
380V/3/50HZ |
|||||
Condenser |
Quantity of Fan(piece) |
2 |
2 |
2 |
2 |
|
Air volume(m³/h) |
2x1800 |
2x3000 |
2x4500 |
2x8720 |
||
Power of Fan(W) |
2x120 |
2x120 |
2x180 |
2x600 |
||
Refrigerating capacity of compressor units |
Evaporating Temperature -15℃ |
Cooling capacity |
5690 |
6810 |
16250 |
19950 |
Power |
3400 |
4170 |
8610 |
11850 |
||
Evaporating Temperature -25℃ |
Cooling capacity |
3800 |
4580 |
10700 |
13650 |
|
Power |
2690 |
3210 |
6870 |
9190 |
||
Evaporating Temperature -35℃ |
Cooling capacity |
2260 |
2750 |
6370 |
8480 |
|
Power |
2020 |
2400 |
5198 |
6940 |
||
Coupling |
Tube couping |
3/8 |
3/8 |
5/8 |
5/8 |
|
Suction coupling |
7/8 |
1-1/8 |
1-3/8 |
1-3/8 |
||
Overall dimensions |
(L)mm Length |
1010 |
1010 |
1430 |
1430 |
|
(B)mm Width |
710 |
710 |
900 |
900 |
||
(H)mm Height |
520 |
570 |
880 |
1080 |
||
Mounting dimensions |
(D)mm Length |
960 |
960 |
1390 |
1390 |
|
(E)mm Width |
420 |
420 |
600 |
600 |
||
Standard configuration of units:compressor,conderser,liquid receiver,pressure controller,pressure gauge,filter,solencid Valve and wirring box,etc. |
Note:
1.Cooling capacity in the form is calculated when the ambient temperature is 32℃.
2.Configuration can be added according to customers’ requirements.
3.When the compressor uses refrigerant R404A,and evaporating temperature lower than -20℃,Cylinder head fan must be installed.
4.Air-cooled Condersing Unit freezer 3-15HP
5.Low Temperature Air-cool Condersing Unit:-5C to -35C